top of page

ÉVALUATION DU MOULE :
où est le champignon[moule] présence?

Mold in Real Estate

 

1. The USEPA has reported that home air can have 100 times more chemicals inside than outside.

 

2. The USEPA has also reported that adults and kids now spend most of their time indoors (90%).

 

3. The CDC has reported that 20+ million adults have asthma, and the National Asthma Survey has reported that asthma is the most prevalent chronic disease among children. These numbers continue to increase annually, suggesting that the indoor environment plays a contributing role in this trend.

 

4. Mold growth can be present within the home and be hidden behind walls or underneath carpeting or flooring.

 

5. The use of Formaldehyde is prevalent in certain building materials and the concentration of this known cancer-causing agent can be many times the safe level.

Photos from recent mold assessments and observations of water infiltration. 

Mold Assessment: Moisture meter reading 54.1% RM

Mold Assessment: Moisture meter reading 54.1% RM

Bathroom exhaust venting into attic space.

Bathroom exhaust venting into attic space.

Mold remediation

Mold remediation

Mold remediator cleaning hard surface.

Mold remediator cleaning hard surface.

Residential flooding:

Residential flooding:

Deteriorated window casing. Fungal spores

Deteriorated window casing a sign of water infiltration. Fungal spores accumulating.

Moisture infiltration at ceiling.

Moisture infiltration at ceiling [peak] intersection, indicates deficiencies with building envelope. Visible compromise in substrate.

Efflorescence on foundation wall

Efflorescence on foundation wall. An indication of moisture presence.

Water leak from floor two bathroom

Surface fungal accumulation on a floor one ceiling, from a second floor water leak.

 AIR SPORE 
ÉCHANTILLONNAGE

Une fuite d'eau dans un appareil peut être découverte à partir d'un étage inférieur ou d'un mur opposé à une fuite de plomberie.

Un exemple d'une telle découverte de fuite d'une telle fuite est représenté à partir d'une caméra de thermographie infrarouge.  Lorsque les joints autour des baignoires échouent, l'eau s'écoule dans la cavité du sol et s'accumule. Si elles ne sont pas contrôlées, les fuites peuvent pourrir les matériaux du sol et le matériau du plafond du niveau inférieur.  

US Environmental Testing LLC Fournit une analyse thermographique infrarouge complète de chaque maison lors de l'inspection de la moisissure, qui révèle ces lacunes critiques et aide à identifier la source des problèmes de moisissure.

rs=w_600,h_800,cg_true.webp

 ÉVALUATION DE L'INFILTRATION D'HUMIDITÉ

bottom of page